The purpose of using best ultrasonic scaler
is to facilitate the removal and elimination of agents which cause
inflammation to the teeth, plaque and its products, as well as calculus.
The term "calculus" is used to refer to a kind of dental plaque that
has hardened over time. This condition is caused by the consistent
accumulation of saliva on the plaque, and which may already be deposited
on the teeth. With the rough surface providing a favorable environment
for the increased formation of calculus, dental ultrasonic scalers make
for a viable choice of equipment fit for use in eliminating this
problem.
Scaling, when done professionally and thoroughly,
ensures that the periodontium is free of harmful agents and disease. The
periodontium is the mass of tissues which surround the teeth and
provide support for the same. As a result of using these ultrasonic
scalers effectively the teeth are maintained securely in the maxillary
and mandibular bones, and which in turn helps to keep your teeth strong.
In
performing its function the tip of the ultrasonic scalers vibrates
following a pattern which depends on the power rating as well as the
type. The water gets energy in the process of passing over the tip in
order to provide cavitations and thus create an action similar to that
of scouring.
Dental ultrasonic scalers work rapidly during the
removal of calculus from the surfaces of the teeth. They do this via
vibration actions ranging between twenty thousand and forty five
thousand times per second. Most of the power, and consequently heat, for
this device is focused at the tip, and which is effectively cooled
using a jet of water. It is thus important to keep the scaling tip in
motion over the teeth because of the heat that it generates. www.oyodental.com,
as well as other professionals in the field, advises that no more than
ten seconds should be spent on the same tooth. In addition to this, only
a single ounce of pressure needs to be used. It is obviously important
to provide and follow the stipulated guidelines and especially when it
comes to people's health. For this reason, this procedure should only be
carried out by professional dentists as any errors may even result in
patients losing their teeth.
As a dental health professional looking for dental ultrasonic scaler,
there is a wide variety of these available in the market, each with its
benefits and drawbacks. They are available in different shapes, with
some actually having interchangeable tips and thus providing added
effectiveness at a lower price, this compared to a situation whereby you
have to buy different devices for the different tips. There are also
new variants which are able to carry their own supply of water. As a
general rule though, finer action is experienced from devices with
thinner tips.
Source:
http://www.oyodental.com/How-Does-A-Dental-Ultrasonic-Scaler-Work
Showing posts with label Ultrasonic Scaler. Show all posts
Showing posts with label Ultrasonic Scaler. Show all posts
Friday, 12 February 2016
Sunday, 10 January 2016
Some Notice For Dental Ultrasonic Scaler DUS-2A
We think Notice for DUS-2A dental ultrasonic scaler is also so important, please pay attention to this!
1 OPERATION NOTICE
a) Autoclave Sterilization is recommended
b) Autoclave Sterilization required first time you use and after each patient as noted below. Take handpiece out of packing bag before sterilization. ONLY Tip, Endo Wrench can be autoclaved under the high temperature and pressure.
c) Please release the scaler tip while pushing the foot pedal.
d) The scaler tip should be firmly tightly and has water output from it
e) The scaler tips should be replaced when it is over wear.
f) Please do not bend or polish the scaler tip
g) Please use pure water for our Ultrasonic scaler
h) If use water bottle to contain pure water, the water bottle should higher than patient’s head for over 1 meter at least.
i) Before install the handpiece, please ensure the cable connector side and cable socket side dry enough.
j) Please do not Pull on the tail line during the operation process in order to avoid the handpiece depart from the connector of cable.
k) Please do not beat or polish the handpiece
l) After the machine finished operation, please turn off the power and then pull out the adapter.
m) Our company is a professional manufacturer for medical devices, we are responsible for all the machines repair and modify as well as spare part replacement.
n) Other factory produced scaler tip may cause the damage of our ultrasonic scaler, please use scaler tip according to DENJOY scaler tip
o) Our machine only accept the power adapter provided by DENJOY DENTAL.
2 CONTRAINDICATION
a) Hemophilia patients can’t use the machine
b) When there is a patient or doctor who is now using the cardiac pacemaker, is forbidden to use this machine
c) The cardiac pacemaker sufferer, pregnancy. the serious cardiac pulse abnormality sufferer and children is forbidden to use this machine.
3 STORAGE AND MAINTENANCE
a) Please handle with care to our ultrasonic scaler, store it at dry environment.
b) Please don’t Storage with toxic, corrosive, flammable, explosive products
c) Environment storage should be not over humidity 80%,atmospheric pressure is 50 kpa-106 kpa, temperature -10 ℃〜+50℃.
d) When the machine is not in use, please turn off the power and pull the power socket, if not use the machine for long period, please charge and use the machine with water at least once each month, each type for 5 minutes at least.
e) Working life span of our machine is 5 years after machine leave our factory.
4 TRANSPORTATION
a) Please avoid too much Shock and vibration, handle with care and avoid inversion during the transportation
b) Do not ship together with dangerous product.
c) Keep away from moist
1 OPERATION NOTICE
a) Autoclave Sterilization is recommended
b) Autoclave Sterilization required first time you use and after each patient as noted below. Take handpiece out of packing bag before sterilization. ONLY Tip, Endo Wrench can be autoclaved under the high temperature and pressure.
c) Please release the scaler tip while pushing the foot pedal.
d) The scaler tip should be firmly tightly and has water output from it
e) The scaler tips should be replaced when it is over wear.
f) Please do not bend or polish the scaler tip
g) Please use pure water for our Ultrasonic scaler
h) If use water bottle to contain pure water, the water bottle should higher than patient’s head for over 1 meter at least.
i) Before install the handpiece, please ensure the cable connector side and cable socket side dry enough.
j) Please do not Pull on the tail line during the operation process in order to avoid the handpiece depart from the connector of cable.
k) Please do not beat or polish the handpiece
l) After the machine finished operation, please turn off the power and then pull out the adapter.
m) Our company is a professional manufacturer for medical devices, we are responsible for all the machines repair and modify as well as spare part replacement.
n) Other factory produced scaler tip may cause the damage of our ultrasonic scaler, please use scaler tip according to DENJOY scaler tip
o) Our machine only accept the power adapter provided by DENJOY DENTAL.
2 CONTRAINDICATION
a) Hemophilia patients can’t use the machine
b) When there is a patient or doctor who is now using the cardiac pacemaker, is forbidden to use this machine
c) The cardiac pacemaker sufferer, pregnancy. the serious cardiac pulse abnormality sufferer and children is forbidden to use this machine.
3 STORAGE AND MAINTENANCE
a) Please handle with care to our ultrasonic scaler, store it at dry environment.
b) Please don’t Storage with toxic, corrosive, flammable, explosive products
c) Environment storage should be not over humidity 80%,atmospheric pressure is 50 kpa-106 kpa, temperature -10 ℃〜+50℃.
d) When the machine is not in use, please turn off the power and pull the power socket, if not use the machine for long period, please charge and use the machine with water at least once each month, each type for 5 minutes at least.
e) Working life span of our machine is 5 years after machine leave our factory.
4 TRANSPORTATION
a) Please avoid too much Shock and vibration, handle with care and avoid inversion during the transportation
b) Do not ship together with dangerous product.
c) Keep away from moist
Subscribe to:
Posts (Atom)